Surface Vertical Rod Ansi Type 2
Surface Vertical Rod LBR Ansi Type 2

Surface Vertical Rod – ANSI Type 2 and Surface Vertical Rod LBR ANSI Type 2
Chassis: | - Corrosion resistant plated steel
|
Touch Pad Rail and Filler: | - Extruded aluminum standard.
- For Roll Formed 630 Satin Stainless Steel. Specify Finish Suffix “F” (See How to Order Guide)
|
Touch Pad: | |
Latches: | - Top Latch — Pullman with dead latching 5/8” (16mm) throw
- Bottom Latch — Pullman with 5/8” (16mm) throw, held retracted during door swing
- Fire Rated LBR device includes 1ea Auxiliary Fire Latch/Pin
|
Backset: | |
Projection: | - 3-1/16” (78mm) projection
- 2-19/32” (66mm) projection when dogged
|
Hand: | - Device is non-handed
- Most trim is non-handed, all handed trim is field reversible
|
Dogging: | - Hex key dogging standard
- Cylinder dogging optional
- No dogging on fire listed devices
|
Maximum Style Width: | |
Door Thickness: | - 1-3/4” For other door thickness applications, contact PDQ Customer Service
|
Door Width: | - Supplied standard for 36” doors , “A” size units available, for maximum door width of 48”
- Consult Door Width Chart to determine correct device for your application
|
Finishes: | - 605 – Polished Brass, 606 – Satin Brass, 613 – Oil Rubbed Bronze, 626 – Satin Chrome, 630 – Satin Stainless Steel
- Optional ‡Antimicrobial Coating available on 626 and 630 finishes only
|
Fasteners: | - Device supplied with sex nuts, machine screws and wood screws
- For Security Screws, contact Customer Service.
|
Mounting Height: | - Device centerline from finished floor: 40” (1016mm)’
|
Vertical Rods: | - 1/2” (13mm) diameter tubular stock for doors up to 7’ Door is Standard. (1’ & 2’ Extension Rods available)
|
Certifications, Listings, Compliances: | - UL/ULC 305 listed for “Panic”, UL10C Listed for “Fire Exit Hardware” up to 3 hours for 4’0” x 10’0” maximum single, 8’0” x 10’0” maximum pairs
- Certified to ANSI/BHMA A156.3-2001 Grade 1
- Florida Building Code HVHZ (High Velocity Hurricane Zone) listed, FL21376. Maximum design load ratings: ± 50 PSF for single doors 3' x 7' and pairs of doors 6' x 7'.
- Meets requirements of the Buy American Act.
|
Warranty: | - Ten (10) year limited warranty
|
Electronic Access Control Options: | - Motorized Latch Retraction and Dogging
- Latch Bolt Monitoring
- Fail Secure/Fail Safe Trim
- Request to Exit/Signal Switches
- Stand Alone Key Pad Trim
- Alarms
|
ANSI Functions – Trim

Architectural Finishes
-
605 (US3) - Bright Brass, Clear Coated
-
606 (US4) - Satin Brass, Clear Coated
-
613 (US10B) - Oil Rubbed Bronze, Oxidized Satin Bronze, Oil Rubbed, No Coating
-
625 (US26) - Bright Chromium Plated, No Coating
-
626 (US26D) - Satin Chrome Plated, No Coating
-
630 (US32D) - Satin Stainless Steel, No Coating
-
622 (US19) - Flat Black
Trim
-
Wide Escutcheon
-
Sectional
-
Grip Pull
-
Pull
-
Plate
Electronic Access Control – Motorized Latch Retraction

Features: | - Ultra Quiet Operation
- For use with PDQ 6200 Wide Stile or 6202 Narrow Stile exit devices, panic and fire listed.
- Unique motor drive retracts Push Pad.
- Dual operation -maintained or momentary operation.
- Supports remote signaled electric dogging.
- Low power requirements. Interfaces with PDQ’s 81440 2A 24VDC Filtered/Regulated Power Supply, and EL Series Electrified Power Transfer Hinges
- Suitable for pairing with Low Energy Power Operators
- Non polarized leads
- On-board diagnostic LED lights
- UL Listed
|
Recommended Power Supply: | - PDQ Model # 81440.
– Input: 120VAC, .9A, 50/60Hz 240VAC, .6.A, 50/60Hz
– Output: 24VDC, 2A, filtered and regulated. - Rated for simultaneous operation of 2ea devices.
- Power Supply Requirements:
– AC/DC Output Voltage – 1A min (filtered and regulated). - 12-24VDC @ < 1A initial surge (1 sec), 5mA standby after 30 sec.
– AC Output Voltage. - 12-24VAC (60Hz) @ < 1A initial surge (1 sec), 15mA standby after 30 sec
|
Electrical Specifications: | - Note: Operating voltage at ± 10% of rated voltage. Input voltage: 24VDC
- Rated in-rush current: 1.0A.
- Operational in-rush current: .85A.
- Continuous current, electric dogging: .4A.
- Recommended Power Supply: PDQ Model # 81440.
Input: 120VAC, .9A, 50/60Hz 240VAC, .6.A, 50/60Hz
Output: 24VDC, 2A, filtered and regulated.
|
Performance: | - Motor drive factory tested to over 500,000 cycles (Over 2 times the ANSI/BHMA 156.25 Grade 1 STD).
|
Electronic Access Control – Escutcheon Wide 199A Series Electrified Locking/Unlocking Trim

Features: | - Designed For Use With PDQ’s 6200 Series Wide Stile Rim, Surface Vertical Rod Exit Devices only. Not available with Concealed Vertical Rod and Mortise Exit Devices.
- PVD (Physical Vapor Deposition) finish offered standard in 605 - Bright Brass, 606 - Satin Brass and 613 - Oil Rubbed Bronze. PVD coated finishes offer outstanding resistance to wear, durability and corrosion.
- Motorized locking/unlocking.
– FAIL SECURE – Outside trim is UNLOCKED when power is ON, and LOCKED when power is OFF. Lockset will lock in the event of a power failure.
– FAIL SAFE – Outside trim is LOCKED when power is ON, and UNLOCKED when power is OFF. Lockset will unlock in the event of a power failure. - Field changeable from FAIL Secure (factory default) to FAIL SAFE.
- Designed for AC or DC input voltage. No need to select voltage when specifying, detailing or ordering.
- SMARTSENSE control board automatically accepts AC or DC input voltage.
|
Performance: | - Motor drive factory tested to over1.4 million cycles (1.4 times the ANSI/BHMA grade 1 std).
|
Electrical Specifications: | - Note: Operating voltage at ± 10% of rated voltage.
- Input voltage: 12-24VDC or 12-24VAC.
- Max In-rush current: < 1.0A.
- Standby current:
– 12VAC: 12mA.
– 24VAC: 10mA.
– 12VDC: 3mA.
– 24VDC: 4mA.
|
Recommended Power Supply: | - PDQ Model # 81440.
– Input: 120VAC, .9A, 50/60Hz 240VAC, .6.A, 50/60Hz
– Output: 24VDC, 2A, filtered and regulated. - Rated for simultaneous operation of 2ea trim assys.
- Power Supply Requirements:
– AC/DC Output Voltage – 1A min (filtered and regulated). - 12-24VDC @ < 1A initial surge (1 sec), 5mA standby
after 30 sec.
– AC Output Voltage. - 12-24VAC (60Hz) @ < 1A initial surge (1 sec), 15mA standby after 30 sec
|
Certifications, Compliances, Listings: | - ANSI/UL10C and CAN/ULC-5104 Listed for “Fire Exit Hardware” up to 3 hours for 4’0” x 8’0” maximum single, 8’0” x 8’0” maximum pairs.
- Certified to ANSI/BHMA A156.3-2008.
- Lever designs comply with ADA (Americans with Disabilities Act) and ICC/ANSI 117.1 for accessible
and Usable Buildings. - Assembled in the U.S.A. with U.S. and foreign material. Meets requirements of the Buy American Act.
|
Electronic Access Control – E629 Series Stand-Alone (Offline) Lockset

Features: | - Designed for use with PDQ 6200 Series RIM and Surface Vertical Rod Exit Devices
- Backlit Stainless Steel keypad buttons standard
- Full Outdoor Standard
- Color LED’s illuminate a visual que when the correct code is entered and low battery life
- Simple installation and programming
- Mechanical Key override
- 3 Hour UL Fire Listed
- Hardwire inputs for 12 or 24V AC or DC are standard
- Operates on 4 AA Alkaline Batteries (Not supplied)
- Up to 100,000 Cycles on one set of batteries
- Standard Mortise Cylinder
|
Electronically Selectable Functions: | - Relock Mode: With any valid credential the lock will unlock for a configurable number of seconds then re-lock.
- Passage Mode: With any valid credential the lock will unlock and remain unlocked until a valid credential is entered to re-lock the device.
- Emergency Lockout Mode: Only the master credential will unlock the door for the configured number of seconds then relock. All other codes are disabled.
|
Users: | - 100 Users + 1 Master Code
|
Input: | - 12-24 VAC/VDC 200mA max current
|
Battery Life: | - 100,000 cycles on a set of (4) AA alkaline batteries (not included).
|
Programming: | - Keypad basic (Option K) models require programming at the lock.
|
Weather Resistance: | - Full outdoor standard - both sides can be exposed to weather.
|
For Doors: | - 1-3/4” standard. For other door thickness, contact PDQ Customer Service
|
Key Override: | |
Keys: | |
Keyways: | - Available in the keyways of most major manufacturers.
|
Interchangeable Core: | - Best type 6 and 7 pin or Schlage LFIC
|
Keying: | - Can be MK, CMK, GMK. Available Zero Bitted (K0), Keyed Different (KD), Keyed Alike (KA).
- Can be keyed into existing masterkey systems of other manufacturers.
|
Finishes: | - 613 (US10B) Oil Rubbed Bronze, 626 (US26D) Satin Chrome
|
Certifications, Listings, Compliances: | - UL 10C listed for “Fire Exit Hardware” labeled for up to 3 hrs, single swing doors 4’0” x 8”0”
- FCC part 15
- PCB RoHS compliant
- PDQ exit devices certified to ANSI/BHMA 156.3-2001, Grade 1
|
Warranty: | - 24 months Limited Warranty
|
Country of Origin: | - Proudly Designed and Assembled by PDQ in the USA.
|
Cross Reference – Surface Vertical Rod Ansi Type 2 and Surface Vertical Rod LBR Ansi Type 2

Note: Effective April 2013, PDQ introduced a revision to exit device trim model numbers.
Below is a cross reference table listing the model numbers used prior to 2013, along with their corresponding new model numbers.


How to Order – Surface Vertical Rod Ansi Type 2 and Surface Vertical Rod LBR Ansi Type 2

/wp-content/uploads/2020/09/Warranty.pdf