Skip to content
    Talk to an Expert

      Electric Strikes

      Talk To An Expert

      Electric Door Strikes for Locks and Exit Devices

      An electric strike is a door frame strike with a keeper that releases electrically, so an access control system can unlock the door without changing the lock. PDQ makes electric door strikes for its cylindrical locks, MR Series mortise locks and 6300 and 6400 rim exit devices. Choose a field changeable fail safe or fail secure strike for locksets, or the 3-hour fire rated 9910 for panic hardware.

      Electric Strikes by Lock Type

      Each strike is sized to one kind of latch. Start with the lock or exit device on the door, then pick the strike built for it.

      PDQ 85001 electric strike for cylindrical locks in 630 satin stainless steel
      Cylindrical Locks

      85001 Electric Strike

      Built for the latch on PDQ Grade 1 and Grade 2 cylindrical locks, including the GT, XGT, SX, GP, SD and SF Series and the GTS and SDS electronic locks.

      • Field changeable from fail secure to fail safe; ships fail secure
      • 12 to 24 VDC; factory tested to 1,000,000 cycles
      • Fits the XGT, GT, SX, GP, SD, SF, GTS and SDS locks

      Best for: Office suite entries and interior access-controlled doors

      PDQ 85003 electric strike for MR Series mortise locks in 630 satin stainless steel
      Mortise Locks

      85003 Electric Strike

      Built for PDQ MR Series mortise locks without a deadbolt. It adds electric release to a mortise opening without changing the lock.

      • Field changeable from fail secure to fail safe; ships fail secure
      • 12 to 24 VDC; factory tested to 1,000,000 cycles
      • Fits the MR Series mortise lock without deadbolt

      Best for: Staff-only and controlled doors with MR Series mortise locks

      PDQ 9910 surface-mounted electric strike for rim exit devices
      Rim Exit Devices

      9910 Electric Strike

      A surface-mounted strike for PDQ 6300 and 6400 rim exit devices on wide and narrow stile doors.

      • Fail secure; 3-hour fire rated; 5-year limited warranty
      • 1,500 lbf static, 70 ft-lb dynamic, 250,000 cycles
      • Fits the 6300R wide stile and 6400R narrow stile rim exit devices

      Best for: Entrances and corridor doors with panic hardware

      Compare PDQ Electric Strikes

      Model FitsFail Safe / Fail SecureVoltageMonitoringFire Rated
      85001 PDQ Grade 1 and Grade 2 cylindrical locksField changeable; ships fail secure12-24 VDC (0.28A @ 12 VDC, 0.14A @ 24 VDC)Not availableNot listed
      85003 PDQ MR Series mortise locks without deadboltField changeable; ships fail secure12-24 VDC (0.28A @ 12 VDC, 0.14A @ 24 VDC)Not availableNot listed
      9910 PDQ 6300 and 6400 rim exit devices, wide and narrow stileFail secure only12/24 VDC or 12-24 VAC (500mA max @ 12 VDC)Not available3-hour

      All three strikes come in 630 (US32D) satin stainless steel. Ask your rep about other finishes. The 85001 and 85003 are factory tested to 1,000,000 cycles. The 9910 is rated 1,500 lbf static, 70 ft-lb dynamic and 250,000 cycles. It surface mounts, fits 1/2" to 3/4" latch projection with the included spacer, and is non-handed.

      Key: Fail secure = locked without power · Fail safe = unlocked without power · VDC / VAC = volts DC / AC

      Ready to spec or order?Find A Sales Rep

      Need Certification Details?

      See every UL, ANSI/BHMA and ADA listing for PDQ hardware in one filterable matrix.

      architechtstockphoto-473849812-612x612

      How to Choose an Electric Strike

      PDQ 8500 Series electric strike for cylindrical and mortise locks

      Step 1

      Match the strike to the lock and the frame

      An electric strike is sized to a latch, so start with the hardware on the door. People often call the pairing an electric strike lock, but the strike and the lock are separate parts. Use the 85001 for PDQ cylindrical locks, the 85003 for MR Series mortise locks without a deadbolt, and the 9910 for 6300 and 6400 rim exit devices. A strike cannot release a deadbolt, so a mortise lock with a deadbolt needs an electrified lock such as the MR199 instead.

      Then check the frame. The 85001 and 85003 installation instructions cover ANSI hollow metal and aluminum jambs. The 85003 prep sits on the latch centerline, which is not the standard ANSI strike prep, so tell your frame supplier before frames are prepped. The 9910 surface mounts on the frame and adjusts up to 1/4" for door misalignment.

      PDQ 9910 fail secure, 3-hour fire rated electric strike for rim exit devices

      Step 2

      Choose fail safe or fail secure, and check the fire rating

      A fail secure electric strike stays locked when power is lost. A fail safe electric strike unlocks. Fire-rated doors must stay latched in a fire, so they need a fail secure strike that carries a fire rating. Use fail safe only on non-rated doors that must open from the outside during an outage.

      The 85001 and 85003 switch between modes in the field and ship fail secure, but they are not listed as fire rated. For a fire-rated opening, use the 9910, which is fail secure only and 3-hour fire rated. PDQ strikes do not include a latch or keeper monitor, so if your access control system needs to report that the door is closed, add a door position switch.

      PDQ PS220 24 VDC power supply for electric strikes and electrified locks

      Step 3

      Plan the power and the rest of the opening

      Match the strike to the voltage the system supplies. The 85001 and 85003 run on 12 or 24 VDC, set by how the leads are wired. The 9910 accepts 12/24 VDC or 12 to 24 VAC, so it is the only PDQ strike that runs on AC.

      A working opening also needs a power supply, a reader or keypad and a controller from your access control system, and often a request to exit (REX) device. The PS220 power supply delivers 2 amps at 24 VDC across two fused outputs, links to the fire alarm, and is UL 294 listed.

      Where PDQ Electric Strikes Fit

      Carhartt corporate office building

      Office Suites

      Suite entries need card or keypad access for tenants and a locked door after hours. Pair the 85001 with a PDQ cylindrical lock, or the 85003 with an MR Series mortise lock, and set the strike to fail secure so the suite stays locked in an outage.

      Aerial view of North Georgia Medical Plaza, a two-story stone and brick medical office building with a covered entrance canopy, large windows, and a landscaped parking lot surrounded by trees.

      Healthcare

      Hospitals and clinics limit access to staff areas and supply rooms without slowing staff down. Add the 85003 to MR Series mortise locks on staff-only doors, and use the 9910 on 6300 and 6400 rim exit devices where corridor doors have panic hardware. People inside still leave freely.

      Street-level photo of Cadillac Lofts, a four-story mixed-use brick building on a corner, with tan and brown brick facade, large ground-floor storefront windows including a Jimmy John's, streetlights, and a fire hydrant in the foreground on a snowy day.

      Multifamily Entries

      Lobby doors and amenity rooms need access for residents and vendors on a schedule. Use the 9910 on rim exit devices at main entries and the 85001 on amenity room doors with cylindrical locks. For unit doors with no wiring, see PDQ Spirit electronic door locks.

      Electric Strike FAQs

      What is an electric strike?

      An electric strike is a strike plate for the door frame with a keeper that releases electrically, so an access control system can let someone through without anyone touching the lock. It replaces the standard strike where the latch catches. The lock itself stays mechanical, which makes electric strikes a common way to add card or keypad access to an opening. PDQ makes electric strikes for cylindrical locks, mortise locks and rim exit devices.

      How does an electric strike work?

      An electric strike works by letting its keeper swing open when the access control system changes the power to it. The latch stays extended, so when the keeper is released the door pushes open and the latch slides out of the strike. When the keeper locks again, the latch holds the door closed as usual. From the inside, people still leave by turning the lever or pushing the exit device.

      What is the difference between fail safe and fail secure?

      A fail secure electric strike stays locked when power is cut, and a fail safe electric strike unlocks when power is cut. Fail secure needs power to open, so the door stays secure in an outage. Fail safe needs power to stay locked, so the door can be opened from the outside in an outage. The PDQ 85001 and 85003 are field changeable between the two and ship fail secure, and the 9910 is fail secure only.

      Does an electric strike need a power supply?

      Yes. An electric strike runs on low-voltage power, usually from a power supply wired through the access control system. The PDQ 85001 and 85003 run on 12 to 24 VDC, and the 9910 runs on 12/24 VDC or 12 to 24 VAC. The PS220 power supply delivers 2 amps at 24 VDC across two fused outputs and links to the fire alarm.

      Can I use an electric strike with a panic bar?

      Yes, if the strike is built for a rim exit device. The PDQ 9910 is designed for 6300 and 6400 rim exit devices on wide and narrow stile doors, and it mounts on the surface of the frame. It is fail secure, and people inside still exit by pushing the bar. Vertical rod exit devices latch at the top and bottom of the door, so they usually need an electrified exit device instead of an electric strike.

      Can electric strikes be used on fire-rated doors?

      Yes, if the strike is fire rated and fail secure. A fire door has to stay latched during a fire, so a fail safe strike that releases when power drops cannot be used on it. The PDQ 9910 is 3-hour fire rated and fail secure only. Confirm that the strike's fire rating matches the door and frame labels before you install it.

      Electrified Hardware Guides

      Person holding a key card up to a card reader above a commercial lever handle
      Guide

      Why the Smartest Hardware Distributors Are Expanding Into Electrified Products Right Now

      Person opening a door with the PDQ Spirit app on a smartphone
      Guide

      How Mobile Access Control is Revolutionizing Door Security

      Complete the Opening

      An electric strike is one part of an access-controlled door. Pair it with PDQ exit devices and electrified hardware for a complete opening.

      PDQ 6300R wide stile rim exit device

      Exit Devices

      Panic hardware for wide and narrow stile doors in rim, vertical rod and mortise styles.

      PDQ PS220 power supply for electrified door hardware

      Electrified Hardware

      Electrified locks, power supplies, power transfers and hinges for access-controlled openings.

      Need Help Choosing an Electric Strike?

      Tell us about your openings and a PDQ rep will help you match strikes to your locks and exit devices, check voltage and fire ratings, and get submittals and pricing.