Solutions / Hospitality
Hotel Door Locks & Hospitality Hardware
PDQ manufactures the hotel door locks, exit devices, and door closers hotels are built on: ANSI/BHMA Grade 1 mortise and cylindrical locks for guest room entry, connecting doors, and back-of-house doors, plus PDQ powered by OEM/ODM technology partners for mobile-key (BLE/NFC) guest room access. Pre-approved by major hotel brands and installed in more than 8,000 properties.
Where PDQ hardware secures a hotel
A hotel isn't one door type. It's six or seven different security requirements under one roof. PDQ manufactures purpose-built hardware for each:
Guest room entry
Grade 1 mortise or cylindrical locks, mechanical or electronic, sized to standard hotel door prep and brand-standard finishes.
Connecting/adjoining doors
Interconnected locks combine a passage latch and deadbolt in one chassis: the standard hardware for the connecting door between adjoining guest rooms.
Meeting & event space
Exit devices and door closers rated for high-traffic, high-cycle use in ballrooms, conference rooms, and pre-function space.
Back-of-house & staff doors
Keyed-alike and master-keyed mechanical hardware for housekeeping, laundry, mechanical rooms, and staff-only corridors, all on one PDQ key system.
Pool, patio & amenity access
Corrosion-resistant finishes and outdoor-rated electronic options for pool gates, fitness centers, and amenity doors exposed to weather and chlorine.
Egress & life safety
UL/cUL fire-rated exit devices and closers keep egress paths code-compliant while electrified options tie into fire-alarm and access-control panels.
Guest room entry
Grade 1 mortise or cylindrical locks, mechanical or electronic, sized to standard hotel door prep and brand-standard finishes.
Connecting/adjoining doors
Interconnected locks combine a passage latch and deadbolt in one chassis: the standard hardware for the connecting door between adjoining guest rooms.
Meeting & event space
Exit devices and door closers rated for high-traffic, high-cycle use in ballrooms, conference rooms, and pre-function space.
Back-of-house & staff doors
Keyed-alike and master-keyed mechanical hardware for housekeeping, laundry, mechanical rooms, and staff-only corridors, all on one PDQ key system.
Pool, patio & amenity access
Corrosion-resistant finishes and outdoor-rated electronic options for pool gates, fitness centers, and amenity doors exposed to weather and chlorine.
Egress & life safety
UL/cUL fire-rated exit devices and closers keep egress paths code-compliant while electrified options tie into fire-alarm and access-control panels.
Mobile-key and smart-lock options through PDQ's OEM/ODM partners
Beyond its own mechanical and Spirit electronic lines, PDQ works with a network of OEM/ODM technology partners to bring wireless, mobile-credential locking, BLE/NFC entry, and PMS-integrated remote check-in to hospitality doors. Because PDQ continues to add technology partners, the current lineup is maintained on one page rather than duplicated here.
Wireless, no-rewire installs
Partner platforms run on battery power over BLE/NFC, so retrofits install on the same door prep as a mechanical lock swap: no wiring back to a head-end panel.
PMS & remote check-in
Partner platforms integrate with property management systems to support mobile keys, remote check-in, and centralized guest access management.
A growing partner network
PDQ's OEM/ODM network spans multiple technology partners with different apps, cloud platforms, and integration paths, so the right fit depends on the credential type and property systems a hotel already runs.
Wireless, no-rewire installs
Partner platforms run on battery power over BLE/NFC, so retrofits install on the same door prep as a mechanical lock swap: no wiring back to a head-end panel.
PMS & remote check-in
Partner platforms integrate with property management systems to support mobile keys, remote check-in, and centralized guest access management.
A growing partner network
PDQ's OEM/ODM network spans multiple technology partners with different apps, cloud platforms, and integration paths, so the right fit depends on the credential type and property systems a hotel already runs.
Standards & compliance for hotel door hardware
|
Requirement |
What it covers |
PDQ compliance |
|---|---|---|
|
ANSI/BHMA A156.13 |
Operational and security grade for mortise locks & latches, including the hotel guest-room lock function |
MR Series certified Grade 1 |
|
ANSI/BHMA A156.2 |
Operational and security grade for cylindrical (bored) locks |
Grade 1 & Grade 2 cylindrical lines available |
|
ANSI/BHMA A156.25 |
Electrified lock performance, cross-referenced to the base mechanical standard |
Applies to PDQ's electrified and Spirit electronic lines |
|
ADA (lever operation) |
Operable without tight grasping, pinching, or twisting of the wrist |
Lever hardware across PDQ's hospitality product lines |
|
UL/cUL fire rating |
Fire-door hardware performance for egress and corridor doors |
Rated exit devices and closers (rating varies by model) |
|
Grade and fire-rating requirements can vary by hotel brand standard, local building code, and door assembly. Confirm specific requirements with your architect of record or PDQ sales rep before finalizing a spec. |
||
Mechanical vs. electrified vs. electronic: which fits which door?
|
Lock type |
Power/wiring |
Typical hotel use |
Credentials |
|---|---|---|---|
|
Mechanical |
None |
Back-of-house, staff, storage, low-traffic service doors |
Mechanical key |
|
Electrified |
Hardwired |
Egress doors tied to fire alarm/access-control panels |
Wired to building access-control system |
|
Electronic (PDQ Spirit) |
Battery, no wiring |
Common-area & interior doors, meeting space, amenity access |
RFID, PIN, smartphone (BLE), key override |
|
Mobile-key (PDQ OEM/ODM partner platforms) |
Battery, no wiring |
Guest room & unit entry doors |
Smartphone (BLE/NFC), with PMS-driven remote check-in |
FAQs
What type of door lock is best for a hotel guest room?
Most hotel guest room doors use a Grade 1 mortise or cylindrical lock certified to ANSI/BHMA A156.13 or A156.2, paired with a keycard, mobile-key (BLE/NFC), or PIN credential. Grade 1 is the highest ANSI/BHMA operational and security rating and is what most major hotel brand standards require for guest room entry doors. PDQ's mechanical MR Series and CL Series are built to this standard, and PDQ's OEM/ODM technology partners add mobile-key options on the same lock body.
Are PDQ's hotel locks ADA compliant?
Yes. PDQ's lever-handle locks, exit devices, and door closers used in hospitality applications are designed to meet ADA operable-force and lever-operation requirements, which is a baseline requirement for public accommodations including hotels.
Can a hotel replace its keycard system with mobile keys without replacing the lock hardware?
It depends on the existing hardware and which OEM/ODM partner platform you choose. PDQ's mobile-key hardware, built with its OEM/ODM technology partners, is a purpose-built mobile-ready lockset (BLE and NFC) rather than a software add-on to an existing keycard lock, so it's installed as a lock replacement on the same door prep, not as an upgrade to an incompatible legacy lock. Hotels planning a keycard-to-mobile transition should have their sales rep confirm door prep and partner-platform compatibility before ordering.
Does PDQ's mobile-key hardware integrate with hotel property management systems (PMS)?
Yes, through PDQ's OEM/ODM technology partners. Partner platforms are built to integrate with major property management systems and, in some cases, provide a portal option for properties on a PMS that isn't natively supported. Confirm current partner options and PMS compatibility with your PDQ sales rep before specifying.
How many hotels use PDQ door hardware?
PDQ hardware is installed in more than 8,000 hotels across major brands including Hilton, Hyatt, Marriott, IHG, Omni, Radisson, Wyndham, and YOTEL, and PDQ's mechanical products are pre-approved to many of these brands' hotel construction and renovation standards.
What's the difference between mechanical, electrified, and electronic locks for hotels?
Mechanical locks operate on a physical key only and require no power or network. Electrified locks add a wired electric strike or trim so the opening can tie into a fire-alarm or access-control panel, typically used on egress and back-of-house doors, not guest rooms. Electronic locks, like PDQ's Spirit line and the mobile-key platforms PDQ builds with its OEM/ODM technology partners, run on battery power and accept RFID, PIN, key, and/or mobile-phone (BLE/NFC) credentials without any wiring, which is why they're the common choice for guest room and unit doors today.
Consult with an Expert
PDQ has secured guest rooms, corridors, and back-of-house doors for major hospitality brands for more than 40 years. Tell us about your next new-build, renovation, or brand-standard rollout, and our team will help you spec the right lock, exit device, or mobile-key option for every door on the property.



